Lead Frame Coating Thickness Measurement gauge for electroplating as well as electroless coatings X-Ray or XDV- Fluorescence Tester is accessible in diverse technical specifications. The range of o Lead Frame Coating is used for non-destructive analyses as well as measurements of coating thickness on very tiny components and structures with complex coating systems.
Applications
General Specification
Intended use:Energy dispersive x-ray fluorescence measuring instrument (EDXRF) to measure thin coatings and coating systems on very small flat structures.
Element range:Aluminum Al (13) to Uranium U (92) - up to 24 elements simultaneously.
Design:Bench-top unit with hood opening upwards and housing with a slot on the side.
X/Y- and Z-axis electrically driven and programmable
Motor-driven changeable filters
Measuring direction:Top down
X-Ray Source/Detection
X-ray tube:Standard: Micro focus tube with tungsten target and beryllium window
Optional: Micro focus tube with molybdenum target and beryllium window
High voltage:Three steps: 10 kV, 30 kV, 50 kV
Primary filter:4x changeable: Ni 10 m (0.4 mils); free; Al 1000 m (40 mils); Al 500 m (20 mils)
X-ray optics:Polycapillary
X-Ray Source/Detection
X-ray detector
Effective detector area
For halo-free capillaries, the radiation intensity for energies of the x-radiation is concentrated on the small measurement spot. For capillaries, indicated as radiation, non halofree intensity with high energies (E > 20 keV) can cover a notably larger area than the nominal measurement spot.
Sample Alignment
Video Microscope: High-resolution CCD color camera for optical monitoring of the dimension location along the Crosshairs with a calibrated scale (ruler), primary beam axis, manual focusing and auto-focus, and spot-indicator, Adjustable LED illumination, Laser pointer (class 1) to support precise specimen placement.
Zoom factor:Up to 1080x (Optical: 30x, 90x, 270x; Digital: 1x, 2x, 3x, 4x)
X-Ray Detection
X-ray detector:Proportional counter tube
Absorber:XULM 240 only: optional cobalt or nickel absorber
Measuring distance:0 - 25 mm (0 - 1 in)
Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.
Evaluation Unit
Standard
Option Supporting Plate PCB
Design
Speedy, programmable XY-stage with pop-out function
Quick, programmable XY-stage with pop-out function and large placement area for measurements on PCBs
Usable sample placement area
Width x depth: 370 mm x 320 mm (14.6 in x 12.6 in)
Width x depth: 620 mm x 530 mm (24.4 in x 20.9 in)
Usable maximum travel
X/Y-axis: 250 mm x 220 mm (9.8 in x 8.7 in) Z-axis: 140 mm (5.5 in)
X/Y-axis: 250 mm x 220 mm (9.8 in x 8.7 in) Z-axis: 140 mm (5.5 in)
Max. travel speed X/Y
60 mm/s (0.2 ft/s)
60 mm/s (0.2 ft/s)
Repeatability precision X/Y
unidirectional: 5 m (0.2 mils) max., 2 m (0.08 mils) typ.
unidirectional: 5 m (0.2 mils) max., 2 m (0.08 mils) typ.
Max. sample weight
5 kg (11 lb), with reduced precision max. 20 kg (44 lb)
5 kg (11 lb), with reduced precision max. 20 kg (44 lb)
Max. sample height
135 mm (5.3 in)
135 mm (5.3 in)
Electrical Data
Dimensions
External dimensions:Width x depth x height [mm]: 660 x 835 x 720 mm (26 x 33 x 28.3 in)
Weight:Approx. 135 kg (297 lb)
Interior dimensions of chamber: Width x depth x height: 580 x 560 x 145 mm (22.8 x 22 x 5.7 in)
Environmental Conditions
Operating temperature:10oC - 40oC / 50oF - 104oF
Storage/Transport temperature:0oC - 50oC / 32oF - 122oF
Admissible air humidity: 95 %, non-condensing
Standards
Approval:Fully protected instrument with type approval according to the German regulations
Product details
| Dimension | 403 x 588 x 444 mm |
| Testing Methodology | Radiographic Testing |
| Brand | Fischer |
| Service Type | Thickness Measurement |
| Value Data Report on | Microstructure |
| Application | Mechanical Engineering |
|
Fischer Measurement Technologies (India) Pvt. Ltd. Fischer Measurement Technologies (India) Pvt. Ltd. Fischer Measurement Technologies (India) Pvt. Ltd. |
Fischer Measurement Technologies (India) Pvt. Ltd. Fischer Measurement Technologies (India) Pvt. Ltd. Mumbai: 9724312808 / 9324639406 Ahmedabad: 9724312808 / 9099086111 |